![]() It, there are some simple steps you can take. The system is not monitored but you want to re-enable If you have security monitoring, schedule a service call with your alarm company at the earliest convenience. Leave the battery and transformer disconnected, Off, and you have no plans for activating and using it, If this was a deactivated home alarm going Likely saved yourself a chunk of change by avoiding a service call fee! You can now decide on your best course of action, based on your situation: Repeat the above steps to remove any electrical and/or batteryĪfter you disable the alarm and all is quiet, you can relax aĬongratulations! You’ve successfully silenced the system, and very If the alarm keeps going off, locate the source of the Move the wire well out of the way, or evenīetter, wrap the bare wire with electrical tape.Īt this point, the alarm system should be completely poweredĭown and silent. You could short out and blow the internal fuse in the transformer. However, don’t allow this wire to come inĬontact with other wires, the circuit board, alarm enclosure, or anything else metal, or This is low voltage, so there is no danger from electrical shock. If you later decide to reconnect the wires, it doesn't matter which wire goes to which terminal if you accidentally reverse them, all will still work just fine. Unlike the battery, AC has no polarity, so your AC wires may be red and black, green and yellow, white and white, etc. Wiggling the connector from side to side while pulling.Īlso, the color of the wires doesn't matter. ![]() Remove one of the leads from the battery by Standard alarm systems, this will be a brick-like unit resting in theīottom of the enclosure. Once the panel is open, locate the back-up battery. The alternative to disconnecting power is to locate and disconnect all keypads, sirens, and other sounders to silence the system. This will cost you a service call charge, but it may be worth it depending on your stress and (dis)comfort level. Call a local alarm company out to open the lid for you.Until it dies, you can tape a towel over the front of the keypad to reduce the beeping sound. This could take a while, depending on the condition it was in when you unplugged the transformer. You can do nothing, and wait for the battery to run dead.You can also use a heavy straight-blade screwdriver to forcibly pry the lid open.If you ever decide to reactivate the system in the future, you can either replace the lock, or simply secure the lid with a screw. You can drill out the lock with a cordless or electric drill and 1/4" bit.If your panel uses a lock and you can’t find the The image below shows an alarm key on the left, and a regular house key on the right. Keys are smaller than house keys and are often simply left on top of It may be held shut with screws, which are easily removed, or secured These usually snap together using hooks or tabs, and come apart easily by inserting a small screwdriver to release them.įor "standard" alarm systems with a metal enclosure, open the lid. Opening the Enclosureįor all-in-one units, disable the alarm by first separating the front face of the unit from its base. You can disconnect its wiring when you open the main If you can’t unplug the transformer, or if you can’t find Sometimes a screw is used to hold the transformer in place if so, Plugged into a wall outlet, usually near the main control unit. If any, will also sound until it times out, usually programmed for 10įor either type of system, disable the alarm by first unplugging Keypads beeping or blaring, with lights flashing, and displaying an ”Alarm”, “ Alarm Memory”, or “ Trouble” condition. In almost all cases, a security system in alarm will have.If you must turn off an alarm system of this kind, have your alarm professional correct the alarm issues and restore the fire protection as soon as possible!īefore trying to disable the alarm system, check to make In these cases, shutting down the alarm system will not only disable alarm functions, it will also disable fire alarm protection. ADDITIONAL WARNING: Many residential burglar alarm systems also have home smoke detectors connected to them. They are intended for use only by the homeowner or other authorized person, to enable them to power down an alarm system in “runaway” condition. WARNING: The instructions below show how to disable the alarm system found in many typical homes, without a code, regardless of make or model.
0 Comments
Leave a Reply. |